CPCCCA3004 - Construct and erect wall frames

TAFE Victoria logo
Unit code: CPCCCA3004 | Study level: TAFE
N/A
Industry
Sunshine
CPCCWHS2001 - Apply WHS requirements, policies and procedures in the construction industry
(Or equivalent to be determined by unit coordinator)
Overview
Enquire

Overview

This unit of competency specifies the skills and knowledge required to plan, prepare, set out, construct and erect load-bearing and non-load-bearing wall frames for the different types of loadings, meeting all relevant requirements of the National Construction Code (NCC), Australian Standards, work health and safety (WHS), and Commonwealth and state or territory legislation.
The unit includes setting out, cutting and fabrication of timber frames and preparation of steel frames and the erection, connection and bracing of frames.
Completion of the general construction induction training program specified by the model Code of Practice for Construction Work is required for any person who is to carry out construction work. Achievement of CPCCWHS1001Prepare to work safely in the construction industry meets this requirement.

Assessment

For Melbourne campuses

Assessment tasks will be designed to reinforce and extend knowledge and skill competence within set and controlled parameters in accordance with each unit’s learning outcomes and performance criteria requirements, including the setting of work based practical application tasks designed to provide evidence of competence outcomes, within periodic and scheduled timelines.

Students will be expected to demonstrate the following required skills:
*setting-out and constructing timber framed walls to a minimum height of 2.4 metres and minimum floor area of 30 square metres to accommodate roof and ceiling members and different types of cladding or linings, including:

  • two external load-bearing walls with one window opening and one door opening in each wall
  • two external straight walls with external intersection
  • two internal non-load-bearing walls encompassing an internal T junction and an external junction
    *setting-out and erecting steel framed walls to a minimum height of 2.4 metres and minimum floor area of 30 square metres to accommodate roof and ceiling members and different types of cladding or linings, including:
  • two external load-bearing walls with one window opening and one door opening in each wall
  • two external straight walls with external intersection
  • two internal non-load-bearing walls encompassing an internal T junction and an external junction

Required reading

The qualified trainer and assessor will provide teaching and learning materials as required in the form of workbooks produced by the Polytechnic and/or via the Polytechnic e-learning system.

As part of a course

This unit is studied as part of the following course(s):

Search for units, majors & minors